System Mechanic v3.6x serial key or number
System Mechanic v3.6x serial key or number
- Overview
Duatene™ Bilayer Mesh
One mesh. Two layers. Many benefits.
Duatene™ bilayer mesh* is a groin hernia repair solution that combines a flexible macroporous onlay, built-in connector, and a rigid underlay.([FOOTNOTE=Based on internal test report #TEX-FP-002, Duatene™ bilayer mesh characterization. June 2017.],[ANCHOR=],[LINK=]),([FOOTNOTE=Based on internal test report #TEX-FP-001, PROLENE™* hernia system characterization. July 2017.],[ANCHOR=],[LINK=]),([FOOTNOTE=Duatene™ Bilayer Mesh [instructions for use]. Trevoux, France: Medtronic; 2017.],[ANCHOR=],[LINK=])
It delivers balance of softness and firmness that’s made to complement your technique — and conform to patient anatomy to support successful outcomes.1-3,([FOOTNOTE=Based on internal test report #43021CR079a, Marketing claims evidence from design validation lab. April 2017.],[ANCHOR=],[LINK=])
Parietene™ DS Composite Mesh
- Overview
Parietene™ DS Composite Mesh
A strong,([FOOTNOTE=Based on internal preclinical test report #T2294CR212, Design validation of Parietene™ DS composite mesh in surgeon labs: Evaluation performed through users test and questionnaire in a simulated use environment using a porcine model (n=7 surgeons). September 2016.],[ANCHOR=],[LINK=]) easy-to-use mesh for open and laparoscopic ventral hernia repairs.([FOOTNOTE=Based on internal preclinical report #T2294CR212. Design validation of Parietene™ DS composite mesh in surgeon labs: Feedback collected from seven independent surgeons in a simulated use environment using a porcine model. September 2016.],[ANCHOR=],[LINK=])
On one side, a macroporous mesh to repair ventral hernia defects. On the other, an absorbable synthetic film to minimize unwanted tissue attachment.([FOOTNOTE=Based on NAMSA study #198929, Minimizing tissue attachment barrier performance, local tissue effects, and tissue integration of Parietene DS composite mesh in a rat cecal abrasion model. Based on occurrencerates of cecal soft tissue attachment to the mesh through macroscopic observations in the rat (n=18 test articles vs. n=12 bare mesh; p<0.05). October 2016.],[ANCHOR=],[LINK=]),†
Two unique sides. One unique mesh.
Versatex™ Monofilament Mesh
- Overview
Versatex™ Monofilament Mesh
A mesh designed to offer a balanced combination of macroporosity, surface density, and mechanical strength for successful hernia repair.
- Overview
Symbotex™ Composite Mesh
Symbotex™ composite mesh provides surgeons improved ease of use, with easy mesh deployment and placement within the abdominal cavity. It also brings optimal performance for patients with excellent tissue integration and minimized visceral attachments.
Symbotex™ mesh is available in a large variety of shapes and sizes for laparoscopic hernia repair, with specific subranges dedicated to laparoscopic and open surgery.
ProGrip™ Laparoscopic Self-Fixating Mesh
- Overview
ProGrip™ Laparoscopic Self-Fixating Mesh
Designed to address key issues in laparoscopic inguinal hernia repair, ProGrip™ laparoscopic self-fixating mesh delivers tack-free fixation over the entire anatomy([FOOTNOTE=0Kolbe, T, Hollinsky, C, Walter, I, Joachim, A, and Rülicke, T. Influence of a new self-gripping hernia mesh on male fertility in a rat model. Surgical Endoscopy 2010; 24: 455-461.],[ANCHOR=],[LINK=]) thus eliminating the pain([FOOTNOTE=Laxa, B, and Jacob, B. An ongoing prospective study evaluating self-gripping mesh (Parietex ProGrip™) without additional fixation during laparoscopic total extraperitoneal (TEP) inguinal hernia repair: initial analysis. IHS 2012 P1620.],[ANCHOR=],[LINK=]),([FOOTNOTE=5Birk, D. Self-gripping mesh in laparoscopic inguinal hernia repair. Technique and clinical outcome of 96 operations. IHS 2012 P-1654.],[ANCHOR=],[LINK=]) and cost([FOOTNOTE=Edwards, C. Self-fixating mesh is safe and feasible for laparoscopic inguinal hernia repair. Surgical Endoscopy and Other Interventional Techniques. Conference: 2011 Scientific Session of the Society of American Gastrointestinal and Endoscopic Surgeons, SAGES San Antonio, TX United States. Conference Start: 20110330 Conference End: 20110402. 25: S324.],[ANCHOR=],[LINK=]) associated with traditional fixation.
Parietex™ Composite Ventral Patch
- Overview
Parietex™ Composite Ventral Patch
Parietex™ Composite ventral patch is a mesh specifically designed for small ventral hernia repair. The shape, size, and the specific fixation and deployment system have been designed for optimal abdominal wall conformability and easy deployment and fixation.([FOOTNOTE=Based on internally sponsored preclinical study report #0506-141814, Report 10 days and 4 weeks implantation study in a porcine model, March 2012, and report #0506-141814, Report 10 days and 4 weeks implantation study – amendment 1, June 2012.],[ANCHOR=],[LINK=])
Parietex ProGrip™ Self-Fixating Mesh
- Overview
Parietex ProGrip™ Self-Fixating Mesh
Parietex ProGrip™ self-fixating mesh delivers security, patient comfort and ease of use. Its advanced microgrip technology provides immediate fixation([FOOTNOTE=Data on file.],[ANCHOR=],[LINK=]) of the entire mesh surface for a secure repair and even distribution of tension for patient comfort. Designed for ease of use, the resorbable polylactic acid (PLA) microgrips enable surgeons to position and place the mesh in under 60 seconds([FOOTNOTE=Philippe Chastan, MD (2006). “Tension-Free Open Inguinal Hernia Repair Using an Innovative Self-Gripping Semi-Resorbable Mesh.” Journal of Minimal Access Surgery; pp 139-43. ],[ANCHOR=],[LINK=]), without the use of additional fixation.([FOOTNOTE=Additional fixation is at the surgeon’s discretion.],[ANCHOR=],[LINK=]) Surgeons and patients can depend on a secure repair with the potential for greater patient comfort.
All Parietex™ products are created from a macroporous polyester material which produce superior cellular proliferation when compared to polypropylene mesh in vitro.([FOOTNOTE=Lefranc, O., Codoro, C., Vernier, A., Hadba, A., Gravagna, P. and Therin, M. (2009). “PET vs. PP Mesh Constructs and Their Influence on L929 Fibroblasts Adhesion and Proliferation.” EHS/AHS. Springer. Berlin, Hernia. 13: 64-72.],[ANCHOR=],[LINK=])
Parietex™ Optimized Composite (PCOx) Mesh
- Overview
Parietex™ Optimized Composite (PCOx) Mesh
Parietex™ Optimized Composite (PCOx) mesh offers a resorbable collagen barrier on one side to limit visceral attachments and a three-dimensional polyester knit structure on the other to promote differentiated tissue ingrowth and ease of use.
Based on the proven performance of original PCO, PCOx is the next generation of Parietex™ Composite mesh. It is engineered to better address surgeon and patient needs in laparoscopic ventral hernia repair. The new design incorporates a more resistant barrier and a proprietary textile design with better visibility and increased strength.([FOOTNOTE=“Comparative study of textile tear and suture strength: Parietex™ Optimized Composite vs Parietex™ Composite.” Covidien internal test report 1003CR053.],[ANCHOR=],[LINK=])
PCOx mesh promotes rapid abdominal wall integration,([FOOTNOTE=Evaluation of the local tissue effects and tissue attachment minimization in a rat caecal adhesion model. BioMatech (NAMSA), France. ],[ANCHOR=],[LINK=]) minimizes visceral attachments([FOOTNOTE=Gonzalez et al. Resistance to adhesion formation: A comparative study of treated and untreated mesh products placed in the abdominal cavity. Hernia (2004) 8: 213–219. This study is sponsored by Covidien. Dr. Ramshaw is a current consultant of Covidien. Dr. Rodeheaver is a former consultant of Covidien.],[ANCHOR=],[LINK=]) and facilitates strong tack fixation.17
- Order Information
Order Code Description Unit of Measure Quantity PCO9FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 9 cm Round Box 1 PCO12FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 12 cm Round Box 1 PCO15FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 15 cm Round Box 1 PCO20FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 20 cm Round Box 1 PCO1510FX Parietex Optimized Composite (PCOx) 15cm x 10cm with Fixation Sutures Box 1 PCO2015FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 20 x 15 cm Rectangle Box 1 PCO2520FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 25 x 20 cm Rectangle Box 1 PCO3020FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 30 x 20 cm Rectangle Box 1 PCO3728FX Polyester with Absorbable Collagen Film and Pre-placed Sutures, 37 x 28 cm Rectangle Box 1 PCO9X Parietex Optimized Composite (PCOx) 9 cm Round Box 1 PCO12X Parietex Optimized Composite (PCOx) 12 cm Round Box 1 PCO15X Parietex Optimized Composite (PCOx) 15 cm Round Box 1 PCO20X Parietex Optimized Composite (PCOx) 20 cm Round Box 1 PCO1510X Parietex Optimized Composite (PCOx) 15 cm x 10 cm Box 1 PCO2015X Parietex Optimized Composite (PCOx) 20 cm x 15 cm Box 1 PCO2520X Parietex Optimized Composite (PCOx) 25 cm x 20 cm Box 1 PCO3020X Parietex Optimized Composite (PCOx) 30 cm x 20 cm Box 1 PCO3728X Parietex Optimized Composite (PCOx) 37 cm x 28 cm Box 1 - Resources
Parietex™ Plug and Patch System
- Overview
Parietex™ Plug and Patch System
The latest addition to the Parietex™ family of synthetic mesh is easy to use, allowing surgeons to maintain their proven technique and designed to deliver enhanced patient comfort and intra-operative security through its unique design.
- Easy to Use: Designed for the standard plug and patch technique.
- Effective: Developed for the proven plug and patch repair that yields low recurrence rates while providing consistent reproducible results.([FOOTNOTE=Zhao, G. (2009) Open Mesh Techniques for Inguinal Hernia Repair: A Meta-Analysis of Randomized Controlled Trials. Annals of Surgery; Vol. 250, Number 1, July 2009.],[ANCHOR=],[LINK=])
- Conforms to Defect: Resorbable microgrips enable plug to conform to the defect size and shape while providing additional security prior to suture fixation.([FOOTNOTE=The disk must be adequately fixated in order to minimize the risk of migration. We recommend the use of nonabsorbable fixation.],[ANCHOR=],[LINK=])
- Order Information
Order Code Description Unit of Measure Quantity PNP6X3 Parietex™ Plug and Patch System - 6.5 cm round plug with keyhole patch Box 3 PNP8X3 Parietex™ Plug and Patch System - 8 cm round plug with keyhole patch Box 3
Parietex™ Optimized Composite Open Skirt (PCO OSx) Mesh
- Overview
Parietex™ Optimized Composite Open Skirt (PCO OSx) Mesh
Parietex™ Optimized Composite Open Skirt (PCO OSx) mesh provides a new level of control during open ventral hernia repair. The open skirted (OS) design has increased rigidity for easier handling during implantation in open incisional and ventral hernia repair.
The skirted flap on the parietal side of the mesh allows for more easily accessible fixation points in the open approach. The skirt provides an area of fixation protected from the viscera on one side and allows fixation to the abdominal wall without disrupting the collagen film.
- Order Information
Order Code Description Unit of Measure Quantity PCO1510OSX Skirted Polyester Mesh with Absorbable Collagen Film, 15 x 10 cm Box 1 PCO2015OSX Skirted Polyester Mesh with Absorbable Collagen Film, 20 x 15 cm Box 1 PCO2520OSX Skirted Polyester Mesh with Absorbable Collagen Film, 25 x 20 cm Box 1
Parietex™ Composite (PCO) Parastomal Mesh
- Overview
Parietex™ Composite (PCO) Parastomal Mesh
Parietex™ Composite (PCO) parastomal mesh is a monofilament mesh providing a custom design for parastomal hernia repair. While ordinary meshes carry the risk of in-growth into the bowel, Parietex™ Composite is coated with a protective collagen-based film to help prevent tissue attachment. Its unique design provides for easy placement of the mesh for parastomal hernia repair.
All Parietex™ products are created from a macroporous polyester material whose properties invite healthy tissue integration and mesh compliance while reducing encapsulation.([FOOTNOTE=William S. Cobb, MD; Kent W. Kercher, MD; and B. Todd Heniford, MD. “The Argument for Lightweight Polypropylene Mesh in Hernia Repair.” Surgical Innovation, Vol 12, No 1 (March), 2005: pp 63-69.],[ANCHOR=],[LINK=])
- Order Information
Order Code Description Unit of Measure Quantity PCOPM15H35 Monofilament Polyester with Absorbable Collagen Film for Direct Stomies, 15 cm/35 mm Box 1 PCOPM15H50 Monofilament Polyester with Absorbable Collagen Film for Direct Stomies, 15 cm/50 mm Box 1
Parietex™ Composite Hiatal (PCO 2H) Mesh
- Overview
Parietex™ Composite Hiatal (PCO 2H) Mesh
Parietex™ Composite (PCO) hiatal mesh makes the surgical treatment of gastroesophageal reflux disease (GERD) and hiatal hernia viable. While ordinary meshes can carry the risk of in-growth into the esophagus, Parietex™ Composite is coated on one side with a protective collagen-based film to help minimize tissue attachment. Its unique design provides for easy placement of the mesh for hiatal hernia repair.
All Parietex™ products are created from a macroporous polyester material whose properties invite healthy tissue integration and mesh compliance while reducing encapsulation.22
- Order Information
Order Code Description Unit of Measure Quantity PCO2H1 Polyester with Absorbable Collagen Film, Heart-Shaped for Hiatal Hernia, 8 x 8 cm (3.1" x 3.1") Box 1 PCO2H3 Polyester with Absorbable Collagen Film, Horseshoe-Shaped for Hiatal Hernia, 9 x 8 cm (3.6" x 3.1") Box 1
Parietex™ Hydrophilic Anatomical Mesh
- Overview
Parietex™ Hydrophilic Anatomical Mesh
Parietex™ mesh provides a custom-designed mesh for laparoscopic inguinal hernia repair. It combines Parietex™ 2D weave with Parietex™ 3D weave.
The 2D weave is lightweight and macroporous with a design that is rigid, making it ideal for laparoscopic applications due to its handling properties.
The 3D weave is also a lightweight, macroporous mesh but has a design that provides compliance and softness. This softness allows for gentle placement over sensitive nerve and vessel structures in the inguinal area.
All Parietex™ products are created from a macroporous polyester material whose properties invite healthy tissue integration and mesh compliance while reducing encapsulation.22
- Order Information
Order Code Description Unit of Measure Quantity TECT1510ADP2L Parietex™ Hydrophilic Anatomical Mesh Left Side, Polyester, 15 x 10 cm Box 1 TECT1612AL Parietex™ Hydrophilic Anatomical Mesh Left Side, Polyester, 16 x 12 cm Box 1 TECT1510ADP2R Parietex™ Hydrophilic Anatomical Mesh Right Side, Polyester, 15 x 10 cm Box 1 TECT1510AL Parietex™ Hydrophilic Anatomical Mesh, Left Side, Polyester, 15 x 10 cm Box 1 TECT1510AR Parietex™ Hydrophilic Anatomical Mesh, Right Side, Polyester, 15 x 10 cm Box 1 TECT1510ADPL Left anatomical mesh with suture (6" x 4") Box 1 TECT1510ADPR Right anatomical mesh with suture (6" x 4") Box 1 TECT1612AR Parietex™ Hydrophilic Anatomical Mesh Right Side, Polyester, 16 x 12 cm Box 1
- Overview
Parietex™ Folding Mesh
Parietex™ folding mesh has a suture to fold the mesh, making insertion into a laparoscopic cannula easier. This design enables ease of placement of the mesh into the surgical site for inguinal hernia repair.
All Parietex™ products are created from a macroporous polyester material whose properties invite healthy tissue integration and mesh compliance while reducing encapsulation.22
- Order Information
Order Code Description Unit of Measure Quantity TEC1410DP Folding Mesh with Slit, 5.6" x 4" Box 1 TEC1410P5 Folding Mesh, 5.6" x 4" Box 1
Lenovo Storage V3700 V2 and V3700 V2 XPProduct Guide (withdrawn product)
- Lenovo Storage V3700 V2 Control Enclosure: 2U rack mount
- Lenovo Storage V3700 V2 XP Control Enclosure: 2U rack mount
- Lenovo Storage V3700 V2 Expansion Enclosure: 2U rack mount
configuration
- 24 SFF drive bays in the control enclosure
- 24 SFF drive bays in the expansion enclosure; up to 10 expansion enclosures
- 12 LFF drive bays in the control enclosure
- 12 LFF drive bays in the expansion enclosures; up to 10 expansion enclosures
Dual-ported 12 Gb SAS drive attachment infrastructure.
Controller unit with two node canisters (ports per one node canister):- 24x 12 Gb SAS internal drive ports (SFF enclosure)
- 12x 12 Gb SAS internal drive ports (LFF enclosure)
- 1x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion port for the attachment of the expansion enclosures
- 24x 12 Gb SAS internal drive ports (SFF enclosure)
- 12x 12 Gb SAS internal drive ports (LFF enclosure)
- 2x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion ports for the daisy chained attachment of the expansion enclosures
- 300 GB, 600 GB, and 900 GB 15K rpm SAS HDDs
- 900 GB, 1.2 TB, 1.8 TB, and 2.4 TB 10K rpm SAS HDDs
- 2 TB 7.2K rpm NL SAS HDDs
- 400 GB, 800 GB, 1.6 TB, and 3.2 TB SAS SSDs
- 1.92 TB, 3.84 TB, 7.68 TB, and 15.36 TB read-optimized SAS SSDs
- 300 GB, 600 GB, and 900 GB 15K rpm SAS HDDs
- 900 GB, 1.2 TB, 1.8 TB, and 2.4 TB 10K rpm SAS HDDs
- 4 TB, 6 TB, 8 TB, 10 TB, and 12 TB 7.2K rpm NL SAS HDDs
- 4x 1 Gb iSCSI host ports (UTP, RJ-45) (2 ports per node canister)
- 4x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644) (2 ports per node canister; V3700 V2 XP only)
- 8x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644) (4 ports per node canister)
- 8x 1 Gb iSCSI host ports (UTP, RJ-45) (4 ports per node canister)
- 8x 10 Gb iSCSI or FCoE SFP+ host ports (SW fiber, LC) (4 ports per node canister)
- 8x 16 Gb FC SFP+ host ports (SW or LW fiber, LC) (4 ports per node canister)
- 4x 25 Gb iSCSI (RoCE) SFP28 host ports (SW fiber, LC) (2 ports per node canister)
- 4x 25 Gb iSCSI (iWARP) SFP28 host ports (SW fiber, LC) (2 ports per node canister)
(V3700 V2 / V3700 V2 XP)*
- Up to 168 000 / 390 000 cache read IOPS
- Up to 65 000 / 114 000 disk read IOPS
- Up to 17 000 / 29 000 disk write IOPS
- Up to 32 000 / 54 000 disk mixed (70% read/30% write) IOPS
- Up to 4.2 / 6.3 GBps sequential disk read throughput
- Up to 1.1 / 1.7 GBps sequential disk write throughput
- Maximum number of storage pools: 1024
- Maximum number of logical volumes: 2048
- Maximum logical volume size: 256 TB
- Maximum number of drives in a RAID array: 16
- Maximum number of RAID arrays: 128
- Maximum number of drives in a distributed RAID array: 128 (including up to 4 spares)
- Maximum number of distributed RAID arrays: 10
- Maximum hot spare drives: No limit
- Maximum number of host ports: 2048
- Maximum number of hosts: 256
- Maximum number of host ports per one host: 32
- Maximum number of snapshots: 2048 (requires an optional license)
- Maximum number of remote mirroring relationships: 2048 (requires an optional license)
Web-based GUI; SSH CLI; SMI-S; SNMP and email notifications.
- Control enclosure (fully configured): 26 kg (57.3 lb)
- Expansion enclosure (fully configured): 26.7 kg (58.9 lb)
IBM System x3650 M3Product Guide (withdrawn product)
IBM DDR3 memory is compatibility tested and tuned for optimal System x performance and throughput. IBM memory specifications are integrated into the light path diagnostics for immediate system performance feedback and optimum system uptime. From a service and support standpoint, IBM memory automatically assumes the IBM system warranty, and IBM provides service and support worldwide.
The IBM System x3650 M3 supports up to nine DDR3 DIMMs when one processor is installed and up to 18 DIMMs when two processors are installed. However, the maximum number of DIMMs is limited by the number of ranks in the DIMMs:
- RDIMMs
- Up to 18 single-rank RDIMMs (nine per processor) for a maximum of 72 GB (18x 4 GB)
- Up to 18 dual-rank RDIMMs for a maximum of 288 GB (18x 16 GB)
- Up to 12 quad-rank RDIMMs for a maximum of 192 GB (12x 16 GB)
- UDIMMs
- Up to 12 dual-rank UDIMMs for a maximum of 48 GB (12x 4 GB)
Each processor has three memory channels, and there are three DIMMs per channel. RDIMMs can be populated three per channel. However, UDIMMs can only be populated two DIMMs per channel. That is, you can have up to 18 RDIMMs installed in the server, but only up to 12 UDIMMs. Mixing UDIMMs and RDIMMs is not supported.
Maximum memory speed is limited by memory speed supported by the specific processor and by the number and type of DIMMs installed (whichever has a lower memory speed rating), as follows:
- Intel Xeon 5600 series processors:
- 1333 MHz when one or two single-rank or dual-rank RDIMMs per channel are installed or one UDIMM per channel is installed
- 1066 MHz when one quad-rank RDIMM per channel is installed or two UDIMMs per channel are installed
- 800 MHz when three single-rank or dual-rank RDIMMs or two quad-rank RDIMMs per channel are installed
The server supports both 1.5 V and 1.35 V DIMMs. Mixing 1.5 V and 1.35 V DIMMs in the same server is supported for Intel Xeon 5600 series processor-based systems, in such a case all DIMMs operate at 1.5 V. Intel Xeon 5500 series processor-based systems do not support 1.35 V DIMMs.
The following memory protection technologies are supported:
- ECC
- ChipKill (for x4-based RDIMMs)
- Memory mirroring
- Memory sparing
If memory mirroring is used then DIMMs must be installed in pairs (minimum of one pair per each CPU), and both DIMMs in a pair must be identical in type and size. If Memory Sparing is used then DIMMs must be installed in sets of three, and all DIMMs in the same set must be identical in type and size. Memory sparing is only supported for Intel Xeon 5600 series processor-based systems.
The following table lists memory options available for x3650 M3 server.
Table 6. Memory options
What’s New in the System Mechanic v3.6x serial key or number?
Screen Shot
System Requirements for System Mechanic v3.6x serial key or number
- First, download the System Mechanic v3.6x serial key or number
-
You can download its setup from given links: